Related Experiment Video
Updated: Feb 9, 2026

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit - a pilot
Lonneke A M Aarts1, Vincent Jeanne, John P Cleary
1Department of Pediatrics, Máxima Medical Center, Veldhoven, The Netherlands.
Background:
Presently the heart rate is monitored in the Neonatal Intensive Care Unit with contact sensors: electrocardiogram or pulse oximetry. These techniques can cause injuries and infections, particularly in very premature infants with fragile skin. Camera based plethysmography was recently demonstrated in adults as a contactless method to determine heart rate.
Aim:
To investigate the feasibility of this technique for NICU patients and identify challenging conditions.
Study Design And Participants:
Video recordings using only ambient light were made of 19 infants at two NICUs in California and The Netherlands. Heart rate can be derived from these recordings because each cardiovascular pulse wave induces minute pulsatile skin color changes, invisible to the eye but measurable with a camera.
Results:
In all infants the heart beat induced photoplethysmographic signal was strong enough to be measured. Low ambient light level and infant motion prevented successful measurement from time to time.
Conclusions:
Contactless heart rate monitoring by means of a camera using ambient light was demonstrated for the first time in the NICU population and appears feasible. Better hardware and improved algorithms are required to increase robustness.
More Related Videos
09:31Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
11:50Clinical Practice Protocol of Creative Music Therapy for Preterm Infants and Their Parents in the Neonatal Intensive Care Unit
Published on: January 7, 2020
Related Concept Videos
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Measuring Reaction Rates
Measurement: Derived Units
Pilot and Numeric Relaying
Measurement: Standard Units