Related Experiment Video
Updated: May 6, 2026

Analysis of Gene Expression Changes in the Rat Hippocampus After Deep Brain Stimulation of the Anterior Thalamic Nucleus
Published on: March 8, 2015
Stereotactic planning software for human neurotransplantation: suitability in 22 surgical cases of Huntington's
William Omar Contreras Lopez1, Guido Nikkhah2, Elisabeth Schültke1
1Department of Stereotactic and Functional Neurosurgery, University Medical Center, Freiburg, Germany Laboratory of Stereotaxy and Interventional Neurosciences, University Medical Center, Freiburg, Germany.
Purpose:
Intrastriatal neural transplantation using multiple grafts is an experimental approach to the treatment of Huntington's disease (HD). Brain atrophy makes stereotactic plans in these patients a tedious procedure with a risk of suboptimal spatial distribution of the grafts in transplantation procedures. Here we present a self-developed software to optimize the surgical stereotactic planning for bilateral neurotransplantation procedures. It allows close to symmetrical distribution of the stereotactic coordinates in relation to the mid-commissural point (MCP), proposing automatically the planning coordinates for the first transplanted hemisphere and mirrored coordinates to be used in the contra-lateral hemisphere.
Methods:
Twenty-two consecutive HD patients underwent bilateral stereotactic striatal transplantation. Two caudate nucleus and four putaminal tracks were planned bilaterally. For the second, contra-lateral transplantation, the coordinates were mirrored in order to determine contralateral targets and trajectories. Intra-individual comparison between software given coordinates and finally used coordinates was performed.
Results:
No statistical significance was found comparing a) the differences between coordinates proposed by the software and the final coordinates and b) the distribution of the transplantation sites in relation to the midline for the right vs. left hemisphere. No intra- or postoperative transplantation-related adverse events occurred.
Conclusions:
The use of model-based and mirrored coordinates allowed optimal spatial distribution of the grafts. Minor changes were required comparing right to left coordinates giving proof-of principle. The initial use of the software suggests that it may be useful in experimental transplantation trials where neural cell grafts are to be implanted into predefined target sites in the human brain, whether unilateral or bilateral.
More Related Videos
07:52Author Spotlight: Advancing Human Brain Modulation – Optimized Protocols for Transcranial Ultrasound Stimulation Experiments
Published on: June 28, 2024
11:24Stem Cell Transplantation Strategies for the Restoration of Cognitive Dysfunction Caused by Cranial Radiotherapy
Published on: October 18, 2011