Related Experiment Video
Updated: Sep 10, 2025

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
A canine head phantom for quality assurance in multiport microbeam radiation therapy: animal phantom fabrication and
John Paul Ortiz Bustillo1,2, Sam Long1, Bernd Frerker1,3,4
1Centre for Medical Radiation Physics, University of Wollongong Australia, Wollongong, New South Wales 2522, Australia.
Abstract:
Objective. This study aims to develop canine radiotherapy phantoms and a dosimetry protocol for synchrotron microbeam radiation therapy (MRT).Approach. Two canine head phantoms were designed based on computed tomography (CT) image sets obtained from veterinary patients. Polylactic acid polymer and calcium sulfate hemihydrate plaster were used to radiologically simulate soft tissue and bone. Fused deposition modeling 3D printing was used to fabricate the external geometry of the head phantoms. CT images of the phantoms were acquired to measure its CT number profile and to create treatment plans. Using a 4 Tesla superconducting multipole wiggler field and in vacuo filters, synchrotron beam was delivered as broad-beam and as microbeam arrays at the imaging and medical beamline of the Australian Synchrotron. The Monte Carlo simulated dose using a hybrid EclipseTMtreatment planning system (TPS) was compared to the experimental measurements.Main results. The head phantoms offer a realistic three-dimensional canine head geometry and CT numbers mimicking soft tissue and bone. Various types of detectors and biological samples can be accomodated, using a series of customizable rectangular inserts. The measured accumulated doses for microbeam irradiation were within +/-2% of the TPS doses, while all the other measured doses were within +/-10% agreement with the TPS doses. The TPS, phantom positioning, and detector uncertainties contributed to the measurement discrepancies.Significance and conclusions. The 3D printed canine phantoms were shown to be useful dosimetry tool for synchrotron MRT end-to-end quality assurance. The development of canine phantoms and dosimetry methodology are critical for the treatment plan optimization required in future veterinary studies. Both the phantoms and the dosimetry protocol are valuable tools in future veterinary MRT trials.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022