A regional blood flow model for glucose and insulin kinetics during hemodialysis

Daniel Schneditz1, Magda Galach, Karl Thomaseth

  • 1From the *Institute of Physiology, Medical University of Graz, Graz, Austria; †Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland; and ‡Institute of Biomedical Engineering of the Italian National Research Council, Padova, Italy.

ASAIO Journal (American Society for Artificial Internal Organs : 1992)
|November 1, 2013
PubMed

Related Concept Videos

Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
4.1K
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models00:57

Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models

Physiological pharmacokinetic models, often called flow-limited or perfusion models, typically assume a swift drug distribution between tissue and venous blood, creating a rapid drug equilibrium. This premise is based on the idea that drug diffusion is extremely fast, and the cell membrane presents no barrier to drug permeation. In this scenario, where no drug binding occurs, the drug concentration in the tissue equals that of the venous blood leaving the tissue. This greatly simplifies the...
511
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
2.2K
Physiology of the Genitourinary System I: Renal Blood Flow and Glomerular Filtration01:29

Physiology of the Genitourinary System I: Renal Blood Flow and Glomerular Filtration

The kidneys are vital organs responsible for regulating blood filtration, waste excretion, and fluid balance, all of which are crucial for maintaining homeostasis. Renal physiology examines renal blood flow, glomerular filtration, and urine formation, ensuring the body’s internal environment remains stable.Renal Blood FlowThe kidneys receive about 20-25% of the cardiac output, typically around 1200 mL of blood per minute in an average adult. Blood flows into the kidneys through the renal...
1.9K
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
1.8K
Two-Compartment Open Model: IV Bolus Administration01:18

Two-Compartment Open Model: IV Bolus Administration

The two-compartment model for intravenous (IV) bolus administration illustrates drug distribution in the body, subdividing it into central and peripheral compartments. This model operates on the concept of two-compartment kinetics. The drug's plasma concentration shows a bi-exponential decline following IV bolus administration, signaling the presence of two disposition processes: distribution and elimination.
The disparity between drug input and the sum of drug transfer rates between...
1.4K