Volumetric apparatus for hydrogen adsorption and diffusion measurements: sources of systematic error and impact of

Alfonso Policicchio1, Enrico Maccallini, Georgios N Kalantzopoulos

  • 1Dipartimento di Fisica, Università della Calabria, Via Ponte P. Bucci, Cubo 31C, 87036 Arcavacata di Rende (CS), Italy.

Related Concept Videos

Adsorption of Gases on Solids01:28

Adsorption of Gases on Solids

Adsorption is a process where molecules, known as the adsorbates, accumulate on a surface, which is referred to as the adsorbent or substrate. Occurring at the solid-gas interface, this phenomenon is crucial in various scientific and industrial contexts. The reverse of adsorption is desorption.Two types of adsorptions exist: physical (physisorption) and chemical (chemisorption). Physisorption involves gas molecules held to the solid's surface by relatively weak intermolecular van der Waals...
297
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.3K
Adsorption Isotherms II01:25

Adsorption Isotherms II

Brunauer, Emmett, and Teller (BET) introduced a theory in 1938 that modified Langmuir's assumptions to explain multilayer physical adsorption. This theory is applicable to Type II isotherms and provides a more realistic picture of adsorption processes. The BET theory assumes a uniform solid surface with localized adsorption sites, where adsorption at one site doesn't affect adsorption at neighboring sites. This theory also allows for the possibility of additional molecules being adsorbed on top...
146
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
2.0K
Propagation of Uncertainty from Systematic Error01:10

Propagation of Uncertainty from Systematic Error

The atomic mass of an element varies due to the relative ratio of its isotopes. A sample's relative proportion of oxygen isotopes influences its average atomic mass. For instance, if we were to measure the atomic mass of oxygen from a sample, the mass would be a weighted average of the isotopic masses of oxygen in that sample. Since a single sample is not likely to perfectly reflect the true atomic mass of oxygen for all the molecules of oxygen on Earth, the mass we obtain from this...
1.4K
Real Gases: Effects of Intermolecular Forces and Molecular Volume Deriving Van der Waals Equation04:01

Real Gases: Effects of Intermolecular Forces and Molecular Volume Deriving Van der Waals Equation

Thus far, the ideal gas law, PV = nRT, has been applied to a variety of different types of problems, ranging from reaction stoichiometry and empirical and molecular formula problems to determining the density and molar mass of a gas. However, the behavior of a gas is often non-ideal, meaning that the observed relationships between its pressure, volume, and temperature are not accurately described by the gas laws.
30.8K