2 L versus 4 L of PEG3350 + electrolytes for outpatient colonic preparation: a randomized, controlled trial
Mayur Brahmania1, George Ou1, Brian Bressler1
1Division of Gastroenterology, Department of Medicine, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada.
Background:
Low-volume bowel preparations are ideal to ensure patient compliance, thus enabling high-quality examinations to be achieved.
Objectives:
To examine the bowel-cleansing efficacy and patient tolerability of split-dose 2 L PEG3350 + electrolytes (PEG3350e) with 15 mg bisacodyl versus split-dose 4 L PEG3350e.
Design:
Single-blinded, noninferiority, randomized, controlled trial.
Setting:
Single site, university-affiliated tertiary care center.
Patients:
A total of 325 consecutive patients undergoing elective outpatient colonoscopy.
Intervention:
2 L of PEG3350e with 15 mg bisacodyl versus 4 L of PEG3350e, both given in a split-dose fashion.
Main Outcome Measurements:
Efficacy and tolerability of a split dose of 2 L of PEG3350e with 15 mg bisacodyl. Efficacy was assessed by using the Boston Bowel Preparation Scale and Ottawa Bowel Preparation Scale. Patient satisfaction and tolerability were assessed by using a short survey.
Results:
A total of 325 patients were included in the intention-to-treat analysis (51% male) with a mean ± standard deviation age of 56 ± 11.2 years. No statistically significant difference in cleanliness was found by using the Boston Bowel Preparation Scale (intention-to-treat, P = .381; per-protocol, P = .387) and the Ottawa Bowel Preparation Scale (intention-to-treat, P = .285; per-protocol, P = .334). Participants receiving 2 L of PEG3350e found the preparation easy to consume and were willing to repeat the procedure more often than the 4-L group (P < .001).
Limitations:
Single-center study looking at outpatient colonoscopies; unable to comment on adenoma detection rate.
Conclusions:
Bowel-cleansing efficacy was similar in both the 2-L and 4-L PEG3350e groups; however, patient tolerability and willingness to repeat preparation were statistically greater with the 2 L of PEG3350e with 15 mg bisacodyl regimen.
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Endoscopic Procedures II: Colonoscopy
Drugs for Treatment of Constipation-Predominant IBS