Related Experiment Video
Updated: May 6, 2026

Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry
Published on: October 15, 2018
Applying charge discrimination with electrospray ionization-mass spectrometry to protein analyses
1Parke-Davis Pharmaceutical Research, Division of Warner-Lambert Company, Ann Arbor, Michigan, U.S.A..
Abstract:
Electrospray ionization with a magnetic sector mass spectrometer and scanning array detector has unique advantages for sensitive analyses of large biomolecules. The ability to discriminate against low charge state ions (smaller peptides, buffers and salts, background ions) allows for detection of more highly charged ions from proteins present at much lower concentration relative to the small ions from buffers and detergents present. Low femtomole detection limits can be achieved for proteins greater than 100 ku. The charge discrimination phenomenon is more pronounced for higher charged ions, and especially for large biomolecules. Although the charge distribution for the monomer (66 ku) and dimer (133 ku) species of bovine serum albumin overlap, both species can be ascertained readily in a mixture because the lower charged monomer ions have higher optimum microchannel plate voltages than the higher charged dimer ions. Protein-containing solutions can be analyzed directly by electrospray ionization-mass spectrometry (ESI-MS) with array detection, which eliminates time-consuming separation and sample cleanup procedures. For example, heme-containing proteins can be directly detected from ESI-MS of human blood (hemoglobin) as well as from raw meat juices (hemoglobin and myoglobin).
More Related Videos
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Capillary Electrophoresis: Instrumentation
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...