A comparison of the peptide fragmentation obtained from a reflector matrix-assisted laser desorption-ionization time-of-flight and a tandem four sector mass spectrometer
Related Experiment Video
Updated: May 6, 2026

Author Spotlight: Enhanced Histone PTM Isomer Identification Through LC-TIMS-ToF MS/MS and PASEF
Published on: January 12, 2024
J C Rousecor1, W Yu, S A Martin
1Genetics Institute, Inc., One Burtt Road, Andover, Massachusetts, USA.
Abstract:
The types, extent, and overall distribution of peptide fragmentation produced by matrix-assisted laser desorption-ionization-postsource decay (MALDI-PSD) on a reflector time-of-flight mass spectrometer were compared with those obtained from high and low energy collision-induced dissociation (CID) on a four-sector mass spectrometer and from liquid secondary ion mass spectrometry (LSIMS) ion source fragmentation and LSIMS metastable ion (MI) decomposition on a two-sector mass spectrometer. The model peptides studied had sequences and compositions that yielded predominantly either N- or C-terminal fragmentation from CID. For des-Arg(1) and des-Arg(9) bradykinin (i.e., H-PPGFSPFR-OH and H-RP-PGFSPF-OH, respectively), the types of fragment ions and the extent to which each type is formed in both MALDI-PSD and low energy CID spectra are remarkably similar. This observation suggests that both methods deposit comparable internal energies (IE) into [M + H](+) precursor ions. The distribution of N-terminal, C-terminal, immonium, and internal fragmentation from MALDI-PSD spectra of des-Arg(1) and des-Arg(9) bradykinin did not change dramatically with respect to the terminal arginine position, contrary to those from LSIMS MI decomposition, high and low energy CID spectra. This observation in combination with the prominent immonium, internal, and minus 17 fragment ion types in PSD indicates that the imparted IE from MALDI and the 14 µs of flight time may promote steady-state decomposition kinetics. Fragmentation distributions of MALDI-PSD spectra are also similar to those in LSIMS spectra. This implies that the distribution of protonation sites in [M + H](+) is comparable for both techniques.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
MALDI-TOF Mass Spectrometry
Mass Spectrum: Interpretation
Mass Spectrometry: Molecular Fragmentation Overview
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...
Mass Analyzers: Common Types