Quantification of amide proton transfer effect pre- and post-gadolinium contrast agent administration
Yee Kai Tee1, Manus J Donahue, George W J Harston
1Institute of Biomedical Engineering Department of Engineering Science, University of Oxford, UK; Centre for Doctoral Training in Healthcare Innovation, University of Oxford, UK.
Purpose:
To compare quantification of the amide proton transfer (APT) effect pre- and post-gadolinium contrast agent (Gd) administration in order to establish to what extent Gd alters quantification of the APT effect.
Materials And Methods:
Four patients with internal carotid stenosis were recruited. APT imaging was acquired pre- and post-contrast in two sessions (before and after surgery) to assess the extent of relaxation time, T1 , change on APT effect calculated using magnetization transfer ratio asymmetry analysis at offsets of ±3.5 ppm relative to water resonance. Statistical and modeling evaluations were performed on the pre- and post-contrast APT effect to study the sensitivity to contrast administration.
Results:
Before surgery, the post-contrast T1 was estimated to drop <10% of the pre-value for the majority of the patients. After surgery, higher post-contrast T1 reductions were observed in all the patients (maximum decrease was about 20% of the pre-value). Consistent differences between pre- and post-contrast were seen in the APT effect quantified using the asymmetry measure in most regions of the brain, with significant differences found in the white matter at the group level and in 25% of the individual patient results.
Conclusion:
APT imaging should be performed prior to Gd administration to avoid potential misinterpretation of the APT effect.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations