Related Experiment Video
Updated: May 6, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Validation of conventional fluoroscopic and ECG criteria for right ventricular pacemaker lead position using cardiac
Benjamin J Pang1, Subodh B Joshi, Elaine H Lui
1Department of Cardiology, Royal Melbourne Hospital, Parkville, Victoria, Australia; The Department of Medicine, University of Melbourne, Victoria, Australia.
Introduction:
It is hypothesized that pacing the right ventricular (RV) septum is associated with less deleterious outcomes than RV apical pacing. Our aim was to validate fluoroscopic and electrocardiography (ECG) criteria for describing pacemaker and implantable cardioverter defibrillator RV "septal" lead position against the proposed gold standard: cardiac computed tomography (CT).
Methods:
Using the conventional fluoroscopic criteria, we intended to place RV nonapical leads on the interventricular septum. Lead positions were later retrospectively analyzed with CT and correlated with ECGs and fluoroscopic projections: posterior-anterior, 40° left anterior oblique (LAO), 40° right anterior oblique (RAO), and left lateral.
Results:
Only 21% (nine of 35) of presumed "septal" RV nonapical leads using the conventional fluoroscopic criteria were on the true septum. A schema developed to define septal position in the RAO fluoroscopic view had high agreement with CT images. ECG criteria had only fair to moderate agreement with CT. The paced QRS duration was significantly longer (P < 0.001) with RV apical pacing (176 ± 10.7 ms), compared to RV nonapical pacing (144.5 ± 14.3 ms).
Conclusion:
Using the conventional fluoroscopic criteria, only a minority of RV leads were implanted on the true RV septum. Instead, aiming for the middle of the cardiac silhouette in the RAO fluoroscopic view, confirming rightward orientation in the LAO view, and having a paced QRS duration <140 ms may allow the implanting cardiologist a simple, more accurate method to achieve true RV septal lead positioning.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Cardiac Catheterization III: Left Heart Catheterization