Related Experiment Video
Updated: Aug 27, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Bachmann's Bundle Versus Right Atrial Appendage Pacing: A Systematic Review and Meta-Analysis
Raam Mannam1, Ravi Medarametla2, Sunil Bogati1
1NYMC-St. Mary's & St. Clare's Health, Denville, New Jersey, USA.
Background:
Right atrial appendage (RAA) pacing remains the default atrial lead position despite evidence that non-physiological atrial activation promotes interatrial dyssynchrony. Bachmann's bundle pacing (BBp) targets the interatrial conduction pathway. We evaluated whether BBp improves electrophysiologic markers of atrial synchrony and whether this is accompanied by a reduction in atrial fibrillation (AF) incidence compared with RAA pacing.
Methods:
Systematic review and meta-analysis of studies comparing BBp with RAA pacing. PubMed, Embase, Scopus, Cochrane Library, ClinicalTrials.gov, and reference lists were searched (December 2025).
Primary Outcome:
P-wave duration change. Secondary: AF incidence.
Safety:
lead dislodgement. Random-effects (REML) models.
Results:
Eight studies comprising 731 patients were analyzed. BBp was associated with a consistent reduction in P-wave duration (primary analysis, 5 independent-group studies: MD -34.61 ms; 95% CI -39.84 to -29.38; p < 0.001; I2 = 0%; 6-study sensitivity including Vedage et al.: MD -35.24 ms; I2 = 0%), indicating a shortening of global atrial activation time. BBp was also associated with a lower AF incidence across three RCTs (RR 0.59; 95% CI 0.37-0.94; p = 0.026); however, this estimate was imprecise and sensitive to removal of the dominant contributing trial. Atrial lead dislodgement was rare and events were insufficient for formal pooled analysis; no excess dislodgement signal was observed, but comparative safety remains uncertain given event sparsity.
Conclusions:
BBp consistently reduced P-wave duration across diverse paced populations and generated a fragile signal toward lower AF incidence. Comparative lead safety is uncertain due to sparse events. These findings support investigation in prospective trials but do not justify immediate practice change.
Prospero Registration:
CRD420261282981.
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Catheterization II: Right Heart Catheterization
Dysrhythmias VI: Management of Dysrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...