Validation of a conical cuff on the forearm for estimating radial artery blood pressure
Lawrence T Hersh1, Jean C Sesing, William J Luczyk
1aGE Healthcare, Milwaukee, Wisconsin bClinimark Physiology Labs, Louisville, Colorado, USA.
Introduction:
There has been a growing need for and interest in measuring noninvasive blood pressure (NIBP) in obese patients. In many situations, available rectangular upper arm blood pressure cuffs do not fit properly, closing in a crisscross manner or overlapping the elbow. To address this issue, GE Healthcare has designed a conically shaped cuff for use on the forearm to estimate radial arterial blood pressure. This study evaluated using this forearm cuff with an oscillometric NIBP algorithm compared with an invasive radial arterial blood pressure reference.
Patients And Methods:
Thirty-four patients were enrolled in the study with an aim to acquire a minimum of 150 paired measurements. Blood pressure was measured and recorded invasively from the radial artery of each patient, while noninvasive oscillometric measurements were acquired from the same limb using a conically shaped cuff placed on the patient's forearm.
Analysis:
NIBP values were compared with the invasive blood pressure values acquired in the combined 30-s period preceding cuff inflation and the 30-s period following cuff deflation. The acceptance criteria for measurement accuracy were defined in accordance with the ANSI/AAMI/ISO 81060-2:2009 standard, which requires an absolute average error of 5 mmHg or less, with an SD of 8 mmHg or less.
Results:
The systolic mean error (-0.82 mmHg) and SD (6.08 mmHg) and the diastolic mean error (1.53 mmHg) and SD (3.83 mmHg) were within the 81060-2 acceptance criteria.
Conclusion:
The statistical results show that oscillometric NIBP measurements taken with the conically shaped cuff placed on the forearm give an accurate estimation of radial arterial blood pressure.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation