Evaluating temperature and duration in arterial tissue fusion to maximize bond strength
James D Cezo1, Anna C Passernig1, Virginia L Ferguson1
1Department of Mechanical Engineering University of Colorado at Boulder, 427 UCB, 1111 Engineering Drive, Boulder, CO 80309-0427, USA.
Abstract:
Tissue fusion is a growing area of medical research that enables mechanical closure of tissues without the need of foreign bodies such as sutures or staples. Utilizing heat and pressure applied for a specified time, a bond can be formed between adjacent tissues. The success or failure of tissue fusion is contingent upon the strength of the bond it creates between opposing tissues, yet little characterization has been done to measure the strength of this interface as a function of the input parameters, such as heat and pressure. Previous studies have examined the strength of tissue fusion using clinically relevant outcomes such as bursting pressure or tearing strength, but none have explored metrics more appropriate for determining the mechanics of the actual bond such as peel or shear strengths. The goal of this study is to establish methodology for T-peel and lap shear testing of fused tissues and measure the fusion bonding strength as a function of temperature and time using the ConMed Altrus(®) laparoscopic thermal fusion device. Across five temperatures (120, 140, 150, 160, 170°C) and four time durations (500, 1000, 1800, 3000ms) the mean peeling strength, ultimate shear strength, and bursting pressure of fused porcine splenic arteries were measured. The shear strength increased with increasing temperature and time with an ultimate shear strength at 160°C and 3000ms equal to 290 ± 99Pa. No trend was observed between the input parameters of time and applied temperature and the mean peeling force, although there were significant differences between groups. The bursting pressure increased significantly with increasing durations, but no trend was noted between temperature and bursting pressure. The shear strength data suggest there is some physical or chemical reaction which occurs in the tissue between 120°C and 150°C which provides a stronger bond. The shear and peel results also reveal that the fusion bond undergoes brittle failure. This study suggests that the tissue fusion bond is maximized at temperatures over 150°C and at a time of 3000ms using the ConMed Altrus(®) and that input parameters can be tuned to optimize the strength of the bonded region.
More Related Videos
08:40Standard Test Method ASTM D 7998-19 for the Cohesive Strength Development of Wood Adhesives
Published on: May 17, 2020
12:22Synthesis of Thermogelling PolyN-isopropylacrylamide-graft-chondroitin Sulfate Composites with Alginate Microparticles for Tissue Engineering
Published on: October 26, 2016
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...