Construction and Evaluation of a Murine Calvarial Osteolysis Model by Exposure to CoCrMo Particles in Aseptic Loosening
Published on: February 17, 2018
Polyethylene particles in joint fluid and osteolysis in revision total knee arthroplasty
Ignasi Piñol1, Alberto Torres1, Gabriel Gil1
1Hospital del Mar. Servei de COT., Passeig Maritim 25-29, Barcelona CP: 08003, Spain.
Background:
One of the most frequent reasons for total knee arthroplasty late failure is osteolysis. It has been related to foreign body reaction to polyethylene particles. The aim of this study is to analyse the number, size and morphology of polyethylene particles in synovial fluid in total knee arthroplasty revision and correlate them to the pathology and the degree of osteolysis.
Methods:
Synovial fluid was obtained in 12 patients before the revision total knee arthroplasty. Polyethylene particles were isolated and analysed through scanning electron microscopy. Samples of synovial tissue were analysed with optical microscopy while considering the parameters of particles and histiocytic infiltration. Osteolysis was analysed with plain radiography and the macroscopic aspect during surgery.
Results:
The statistical analysis showed a significant correlation between a high concentration of polyethylene particles in synovial fluid and a high degree of osteolysis. The concentration of particles in synovial fluid also showed a significant correlation with a high degree of particles and histiocytes in the histological analysis. There was a relationship between the size of particles and the degree of osteolysis. No relationship was found between the shape of the particles and the histological findings or the degree of osteolysis.
Conclusions:
In an "in vivo" TKA scenario, the presence of a high concentration of polyethylene particles in the synovial fluid seems to be the cause of a highly active foreign body histological reaction, with an increased number of histiocytes, which seems to be the cause of a significant degree of osteolysis around the implant.