Atrial lead dislodgement with a DDD pacemaker.

A J Greenspon, J Cox, R M Greenberg

    Pacing and Clinical Electrophysiology : PACE
    |May 1, 1986
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Optimizing Pre-Operative Clinical Staging in Resectable Non-Small Cell Lung Cancer (NSCLC): A Retrospective Cohort Study.

    Thoracic cancer·2025
    Same author

    Correction: Optimum dose of vitamin D for disease prevention in older people: BEST-D trial of vitamin D in primary care.

    Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA·2025
    Same author

    Achievement of Target Gain Larger than Unity in an Inertial Fusion Experiment.

    Physical review letters·2024
    Same author

    Mycobacterial formation of intracellular lipid inclusions is a dynamic process associated with rapid replication.

    bioRxiv : the preprint server for biology·2023
    Same author

    Patient-reported outcome measures (PROMs) in radiology: embracing the metrics of change.

    Clinical radiology·2023
    Same author

    Diagnosis of venous thromboembolism in pregnancy: a review of current guidelines.

    Clinical radiology·2022
    Same journal

    A Case of Permanent Pacemaker Implantation via the Epicardial Approach Using the 3830 Lead in an 11-Day-Old Neonate (With Follow-Up of the Above Case).

    Pacing and clinical electrophysiology : PACE·2026
    Same journal

    Cryoballoon Versus Radiofrequency Ablation for Persistent Atrial Fibrillation: Meta-Analysis of Randomized Trials.

    Pacing and clinical electrophysiology : PACE·2026
    Same journal

    Tilt Test Duration in Suspected Vasovagal Syncope: Temporal Patterns and Diagnostic Yield in Patients From Central China.

    Pacing and clinical electrophysiology : PACE·2026
    Same journal

    Combined Leadless Pacing and Subcutaneous ICD Therapy in Long QT Syndromes.

    Pacing and clinical electrophysiology : PACE·2026
    Same journal

    Association of Anesthesia Modality With Procedural Parameters and Clinical Outcomes in PVI for Atrial Fibrillation.

    Pacing and clinical electrophysiology : PACE·2026
    Same journal

    Zero-Fluoroscopy Cryoballoon Ablation for Paroxysmal Atrial Fibrillation in a Patient With Dextrocardia: A Case Report.

    Pacing and clinical electrophysiology : PACE·2026
    See all related articles

    Pacemaker lead dislodgement can cause unusual heart rhythms. A pacemaker

    Area of Science:

    • Cardiology
    • Biomedical Engineering

    Background:

    • A patient with a history of aortic valve surgery underwent DDD pacemaker implantation for complete heart block.
    • An active fixation atrial J electrode was utilized for lead placement.

    Observation:

    • The patient presented with an unusual electrocardiographic rhythm characterized by two distinct QRS morphologies.
    • Standard chest X-rays did not reveal any changes in lead positioning.

    Findings:

    • Analysis of the pacemaker's MARKER CHANNEL revealed atrial lead dislodgement as the cause of the alternating QRS morphologies.
    • This finding highlights the potential for atrial active fixation leads to become dislodged post-implantation.

    Implications:

    • Unusual electrocardiographic rhythms may indicate pacemaker lead dislodgement.

    Related Experiment Videos

  • Utilizing the MARKER CHANNEL of a pacemaker can be a valuable diagnostic tool for identifying lead-related issues.
  • Awareness of this complication is crucial for clinicians managing patients with pacemakers.