High Accuracy Molecular Weight Determination and Variation Characterization of Proteins Up To 80 ku by Ionspray Mass
1Bioteclmology Research Institute, National Research Council of Canada, 6100 Royaimounl Avenue, H4P 2R2, Montreal, Quebec, Canada.
Abstract:
A quadrupole mass spectrometer with an ionspray interface was used to measure the molecular weight (MW) of proteins up to 80,000 u . With the improvements in instrument cahbration by a statistical averaging method and in data analysis by a gaussian curve-fitting method, precision of MW determination as high as 12 ppm was achieved with equine myoglobin (MW 16,950.4 ± 0.2 u). Exact MW determination of three components in cerato-ulmin revealed that the two minor ones had lost amino acid residues Ser and Ser-Asp, respectively, from the major component (MW 7618.4 ± 0.2 u). MW classifIcation of eight components in the Fab fragment of a monoclonal antibody revealed that one set of four had MW - 47,540 u and the other - 47,640 u. The MW difference of 100.2 ± 0.6 u between fragment 1 and 2, attributed to inhomogeneous cleavage at the Fab C-terminus, was probably due to one additional Thr in 1. The MW of bovine serum albumin (BSA) was found to be 66,431.5 ± 1.3 u, - 164 u higher than the calculated sequence MW, most probably because of the incorrectness in the previously reported BSA amino acid sequence. The MW of human serum transferrin (79,556.8 ± 1.7 u) was shown to be 4414 u higher than the sequence MW, pointing to a glycosylation of 22.7 sugar units in this protein. The greater complexity in bovine serum transferrin (MW 78,030.5 ± 1.8 and 78,326 ± 3.3 u for the two major components) was correlated with the heterogeneity in the glycosylation.
More Related Videos
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight MALDI-TOF Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
10:05Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
Published on: October 24, 2018
Related Concept Videos
High-Resolution Mass Spectrometry (HRMS)
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Overview
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...