Related Experiment Video
Updated: May 5, 2026

Image Acquisition using Portable Sonography for Emergency Airway Management
Published on: September 28, 2022
Tracheal palpation to assess endotracheal tube depth: an exploratory study
William P McKay1, Jim Klonarakis, Vladko Pelivanov
1Department of Anesthesia, RUH, University of Saskatchewan, 103 Hospital Dr., Saskatoon, SK, S7N 0W8, Canada, bill.mckay@usask.ca.
Purpose:
Correct placement of the endotracheal tube (ETT) occurs when the distal tip is in mid-trachea. This study compares two techniques used to place the ETT at the correct depth during intubation: tracheal palpation vs placement at a fixed depth at the patient's teeth.
Methods:
With approval of the Research Ethics Board, we recruited American Society of Anesthesiologists physical status I-II patients scheduled for elective surgery with tracheal intubation. Clinicians performing the tracheal intubations were asked to "advance the tube slowly once the tip is through the cords". An investigator palpated the patient's trachea with three fingers spread over the trachea from the larynx to the sternal notch. When the ETT tip was felt in the sternal notch, the ETT was immobilized and its position was determined by fibreoptic bronchoscopy. The position of the ETT tip was compared with our hospital standard, which is a depth at the incisors or gums of 23 cm for men and 21 cm for women. The primary outcome was the incidence of correct placement. Correct placement of the ETT was defined as a tip > 2.5 cm from the carina and > 3.5 cm below the vocal cords.
Results:
Movement of the ETT tip was readily palpable in 77 of 92 patients studied, and bronchoscopy was performed in 85 patients. Placement by tracheal palpation resulted in more correct placements (71 [77%]; 95% confidence interval [CI] 74 to 81) than hospital standard depth at the incisors or gums (57 [61%]; 95% CI 58 to 66) (P = 0.037). The mean (SD) placement of the ETT tip in palpable subjects was 4.1 (1.7) cm above the carina, 1.9 cm (1.5-2.3 cm) below the ideal mid-tracheal position.
Conclusion:
Tracheal palpation requires no special equipment, takes only a few seconds to perform, and may improve ETT placement at the correct depth. Further studies are warranted.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...

