Related Experiment Video
Updated: May 5, 2026

Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Effective anticoagulation for a percutaneous ventricular assist device using a heparin-based purge solution
Douglas L Jennings1, Carrie W Nemerovski, James S Kalus
1Department of Pharmacy Practice, Nova Southeastern University, Fort Lauderdale, FL, USA.
Insights
A new heparin protocol for Impella support effectively anticoagulated patients with cardiogenic shock, preventing bleeding and clotting events. This approach ensures safe and stable anticoagulation during critical circulatory support.
Area of Science:
- Cardiology
- Biomedical Engineering
- Pharmacology
Background:
- Cardiogenic shock necessitates advanced circulatory support, such as the Impella device.
- Effective anticoagulation is crucial for patients on mechanical circulatory support to prevent thrombotic complications.
Observation:
- A novel anticoagulation protocol was implemented in four patients requiring Impella support for cardiogenic shock.
- The protocol integrated a heparin-based purge solution into the total hourly heparin dosage.
- Despite prolonged support and frequent adjustments by the Automated Impella Controller, patients maintained stable anticoagulation (aPTT).
Findings:
- All four patients survived to hospital discharge without significant bleeding or thromboembolic events.
- No device malfunctions or pump clotting occurred during support.
- The protocol successfully managed anticoagulation in patients with cardiogenic shock, including those with myocardial infarction and severe aortic valvular disease.
Implications:
- This novel heparin protocol offers a safe and effective anticoagulation strategy for Impella device use.
- Standardizing anticoagulation protocols that account for purge solution heparin is vital for optimizing patient outcomes.
- This approach may reduce the risk of complications and improve survival in critically ill patients requiring mechanical circulatory support.
Objective:
To report on a series of patients who were successfully anticoagulated with a novel protocol including a heparin-based purge solution.
Case Summary:
Four patients were supported for a total of 300 hours on the new Impella anticoagulation protocol, which was based on our current nurse-driven cardiology heparin protocol. Three patients were in cardiogenic shock after acute myocardial infarction, and 1 patient was in shock from severe aortic valvular disease. Despite prolonged cardiogenic shock, none of the patients developed significant renal or liver dysfunction while on device support. All 4 patients survived to hospital discharge, and there were no significant bleeding or thromboembolic events. Furthermore, there were no device malfunctions or clotting events within with pump motors. Despite frequent changes to the purge solution flow rate by the Automated Impella Controller, the patients in our cohort had relatively stable activated partial thromboplastin time values.
Discussion:
Our novel anticoagulation protocol, which incorporates the heparin included in the purge solution into the total hourly heparin dosage, was successful in the first cohort of patients receiving extended Impella support for cardiogenic shock. Our case series also highlights that the Automated Impella Controller makes frequent adjustments to the purge solution, which depending on the heparin concentration, can result in significant fluctuations in the patient's total hourly heparin dosage. Furthermore, balancing the heparin in the purge solution with the intravenous heparin is important to ensuring adequate anticoagulation in patients supported by the Impella devices in the intensive care unit.
Conclusions:
Development of a standardized anticoagulation protocol for the Impella device that factors the heparin-based purge into the total heparin dosage and makes appropriate adjustments based on the fluctuating rate of the purge solution can provide effective anticoagulation to patients receiving extended circulatory support from this device.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care