Related Experiment Video
Updated: May 5, 2026

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Biomechanical analyses of static and dynamic fixation techniques of retrograde interlocking femoral nailing using
Kao-Shang Shih1, Ching-Chi Hsu2, Tzu-Pin Hsu3
1Department of Orthopedic Surgery, Shin Kong Wu Ho-Su Memorial Hospital, Taipei 111, Taiwan, ROC; College of Medicine, Fu Jen Catholic University, Taipei 242, Taiwan, ROC; School of Medicine, Taipei Medical University, Taipei 110, Taiwan, ROC; Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei 106, Taiwan, ROC.
Abstract:
Femoral shaft fractures can be treated using retrograde interlocking nailing systems; however, fracture nonunion still occurs. Dynamic fixation techniques, which remove either the proximal or distal locking screws, have been used to solve the problem of nonunion. In addition, a surgical rule for dynamic fixation techniques has been defined based on past clinical reports. However, the biomechanical performance of the retrograde interlocking nailing systems with either the traditional static fixation technique or the dynamic fixation techniques has not been investigated by using nonlinear numerical modeling. Three-dimensional nonlinear finite element models were developed, and the implant strength, fixation stability, and contact area of the fracture surfaces were evaluated. Three types of femoral shaft fractures (a proximal femoral shaft fracture, a middle femoral shaft fracture, and a distal femoral shaft fracture) fixed by three fixation techniques (insertion of all the locking screws, removal of the proximal locking screws, or removal of the distal locking screws) were analyzed. The results showed that the static fixation technique resulted in sufficient fixation stability and that the dynamic fixation techniques decreased the failure risk of the implant and produced a larger contact area of the fracture surfaces. The outcomes of the current study could assist orthopedic surgeons in comprehending the biomechanical performances of both static and dynamic fixation techniques. In addition, the surgeons could also select a fixation technique based on the specific patient situation using the numerical outcomes of this study.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
05:34A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019