Related Experiment Video
Updated: May 5, 2026

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Voltammetric behavior of uric acid on carbon paste electrode modified with salmon sperm dsDNA and its application as
Maryam Mohamadi1, Ali Mostafavi2, Masoud Torkzadeh-Mahani3
1Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran; Young Research Society, Shahid Bahonar University of Kerman, Kerman, Iran.
Abstract:
A simple and sensitive label-free electrochemical DNA biosensor was proposed for the rapid determination of uric acid (UA) using a carbon nano tube paste electrode (CNTPE) modified with salmon sperm dsDNA. At first, the interaction between UA and the DNA was studied using differential pulse voltammetry (DPV). The addition of the DNA to UA solution resulted in a decrease in the peak current of UA and at the same time, a positive shift in the peak potential indicating an intercalative interaction. Then, the voltammetric response of a DNA-immobilized CNTPE was investigated for the determination of UA. The immobilization of the DNA was carried out using acid-functionalized carbon nanotubes and studied using Fe(CN)6(3-)/Fe(CN)6(4-) redox indicator. Compared with unmodified CNTPE, the oxidation signal of UA showed a significant increase at the DNA-coated electrode, and shifted to more positive potentials attributed to the pre-concentration of UA at the electrode surface due to interaction with the surface-confined DNA layer. This interaction was used for the fabrication of a simple and sensitive biosensor for determining UA. After the optimization of operational parameters, a linear dependence of the peak current on the UA concentration was observed in the range of 7.0×10(-7) to 1.1×10(-4) mol L(-1), with the detection and quantification limits of 1.8×10(-7) and 5.8×10(-7) mol L(-1), respectively. The proposed biosensor was successfully applied to validate its capability for the analysis of UA in human serum and urine samples.
More Related Videos
10:02Quantitative SERS Detection of Uric Acid via Formation of Precise Plasmonic Nanojunctions within Aggregates of Gold Nanoparticles and Cucurbit[n]uril
Published on: October 3, 2020
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Pulse Voltammetry
Potentiometry: Membrane Electrodes