External quality assurance programs as a tool for verifying standardization of measurement procedures: Pilot
C Perich1, C Ricós2, V Alvarez3
1SEQC-Analytical Quality Commission, Barcelona, Spain; Laboratori Clínic Bon Pastor, Barcelona, Spain.
Introduction:
Current external quality assurance schemes have been classified into six categories, according to their ability to verify the degree of standardization of the participating measurement procedures. SKML (Netherlands) is a Category 1 EQA scheme (commutable EQA materials with values assigned by reference methods), whereas SEQC (Spain) is a Category 5 scheme (replicate analyses of non-commutable materials with no values assigned by reference methods).
Aim:
The results obtained by a group of Spanish laboratories participating in a pilot study organized by SKML are examined, with the aim of pointing out the improvements over our current scheme that a Category 1 program could provide.
Method:
Imprecision and bias are calculated for each analyte and laboratory, and compared with quality specifications derived from biological variation.
Results:
Of the 26 analytes studied, 9 had results comparable with those from reference methods, and 10 analytes did not have comparable results. The remaining 7 analytes measured did not have available reference method values, and in these cases, comparison with the peer group showed comparable results. The reasons for disagreement in the second group can be summarized as: use of non-standard methods (IFCC without exogenous pyridoxal phosphate for AST and ALT, Jaffé kinetic at low-normal creatinine concentrations and with eGFR); non-commutability of the reference material used to assign values to the routine calibrator (calcium, magnesium and sodium); use of reference materials without established commutability instead of reference methods for AST and GGT, and lack of a systematic effort by manufacturers to harmonize results.
Conclusions:
Results obtained in this work demonstrate the important role of external quality assurance programs using commutable materials with values assigned by reference methods to correctly monitor the standardization of laboratory tests with consequent minimization of risk to patients.
More Related Videos
09:34Implementation of Portable Emissions Measurement Systems PEMS for the Real-driving Emissions RDE Regulation in Europe
Published on: December 4, 2016
05:47Simulation of a Scaled Assembly Process with Collaboration of a Robotic Arm and Monitoring through a Vision System for Quality Control
Published on: August 29, 2025
Related Concept Videos
Data Validation
Key parameters for method validation include:
Measurement: Standard Units
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Uncertainty in Measurement: Reading Instruments
Reliability and Validity