Related Experiment Video
Updated: May 5, 2026

In vivo Evaluation of Mucociliary Clearance in Mice
Published on: December 18, 2020
Computed tomography scans as an objective measure of disease severity in chronic rhinosinusitis
Micah M Likness1, John F Pallanch, David A Sherris
1State University of New York at Buffalo, Department of Otolaryngology, Buffalo, New York, USA.
Objectives:
A truly objective method of measuring disease severity in chronic rhinosinusitis (CRS) has only recently existed. We evaluated computed tomography (CT) scans of CRS patients using this novel objective 3D computerized system and compared results with a novel 2D computerized analysis of a single coronal slice through the osteomeatal complex (OMC) and subjective methods including Lund-Mackay and Zinreich's modified Lund-Mackay.
Study Design:
Prospective multicenter study.
Setting:
Two academic tertiary referral centers.
Subjects And Methods:
Forty-six adults with a diagnosis of CRS underwent CT examination and received an intramuscular triamcinolone injection, dosage weight dependent, followed by CT scan 4 to 5 weeks later. Recruitment lasted 21 months. Scans were evaluated with all 4 scoring methods over 5 months.
Results:
The Lin's concordance class correlation (CCC) of the OMC method revealed the best correlation to the 3D volumetric computerized values (0.915), followed by the Zinreich (0.904) and Lund-Mackay methods (0.824). Posttreatment results demonstrated that both the OMC (0.824) and Zinreich's (0.778) methods had strong agreement with the 3D volumetric methods and were very sensitive to change, whereas the Lund-Mackay (0.545) had only moderate agreement.
Conclusion:
Computerized CT analysis provides the most comprehensive, objective, and reproducible method of measuring disease severity and is very sensitive to change induced by treatment intervention. A 2D coronal image through the OMC provides a valid, user-friendly method of assessing CRS and is representative of CRS severity in all sinuses. Zinreich's subjective method correlated well overall, but the Lund-Mackay method lagged behind in disease representation and sensitivity to change.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

