Noise pollution in intensive care units and emergency wards
Gholamreza Khademi1, Masoumeh Roudi, Ahmad Shah Farhat
1Department of pediatrics, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran.
Introduction:
The improvement of technology has increased noise levels in hospital Wards to higher than international standard levels (35-45 dB). Higher noise levels than the maximum level result in patient's instability and dissatisfaction. Moreover, it will have serious negative effects on the staff's health and the quality of their services. The purpose of this survey is to analyze the level of noise in intensive care units and emergency wards of the Imam Reza Teaching Hospital, Mashhad.
Procedure:
This research was carried out in November 2009 during morning shifts between 7:30 to 12:00. Noise levels were measured 10 times at 30-minute intervals in the nursing stations of 10 wards of the emergency, the intensive care units, and the Nephrology and Kidney Transplant Departments of Imam Reza University Hospital, Mashhad. The noise level in the nursing stations was tested for both the maximum level (Lmax) and the equalizing level (Leq). The research was based on the comparison of equalizing levels (Leq) because maximum levels were unstable.
Results:
In our survey the average level (Leq) in all wards was much higher than the standard level. The maximum level (Lmax) in most wards was 85-86 dB and just in one measurement in the Internal ICU reached 94 dB. The average level of Leq in all wards was 60.2 dB. In emergency units, it was 62.2 dB, but it was not time related. The highest average level (Leq) was measured at 11:30 AM and the peak was measured in the Nephrology nursing station.
Conclusion:
The average levels of noise in intensive care units and also emergency wards were more than the standard levels and as it is known these wards have vital roles in treatment procedures, so more attention is needed in this area.
More Related Videos
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Pneumonia I: Introduction
Risk Factors
Various factors influence the likelihood of developing pneumonia. Age plays a crucial role, with infants, children under two, and individuals over 65 at increased risk due to their...
Pneumonia I: Introduction
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...