Frictional resistance in monocrystalline ceramic brackets with conventional and nonconventional elastomeric ligatures
Mariana Bulhoes Galvão1, Matteo Camporesi, André Tortamano
1Department of Orthodontic, University of Florence, Via Ponte di Mezzo 46/48, Florence, 50100, Italy. matteo_camporesi@yahoo.it.
Background:
The objective of this study was to compare the frictional forces generated by three types of monocrystalline ceramic brackets coupled with conventional elastomeric ligatures (CEL) and nonconventional elastomeric ligatures (NCEL) during the alignment of apically displaced teeth at the maxillary arch.
Methods:
All tests (a total of 480 tests) were carried out in a dry state on a universal testing machine with a testing model consisting of three 0.022-in. monocrystalline ceramic preadjusted brackets (from the maxillary right second premolar through the right central incisor). The canine bracket was bonded to a sliding bar that allowed for different vertical positions. The frictional forces generated by a 0.012- and 0.014-in. superelastic nickel titanium wire (SENT) with conventional and nonconventional ligatures at various amounts of canine misalignment (1.5, 3.0, 4.5, and 6.0 mm) were recorded. Comparisons between the different types of bracket-wire-ligature systems were carried out by means of analysis of variance on ranks with Tukey's post hoc test (P<0.05).
Results:
No significant differences were assessed among the three types of monocrystalline brackets with NCEL when coupled with 0.012-in. SENT. Radiance brackets with NCEL coupled with 0.014-in. SENT showed significantly greater frictional force than Inspire Ice brackets and Pure brackets with NCEL. A significantly greater amount of frictional force was generated with CEL when compared with NCEL for all the tested variables, with the exception of the Pure brackets with 0.012-in. SENT at 1.5 and 3.0 mm of canine misalignment where similar frictional forces were found.
Conclusions:
Nonconventional elastomeric ligatures are able to reduce friction in monocrystalline ceramic brackets.
More Related Videos
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Related Concept Videos
Frictional Force
Characteristics of Dry Friction
Before the wheelbarrow starts moving, the static frictional force acts tangentially to the contact surface, opposing the force that is about to induce the motion. This frictional force prevents the...