Ventilator settings and monitoring parameter targets for initiation of continuous mandatory ventilation: a
Louise Rose1, Lisa Kenny2, Gordon Tait3
1Lawrence S. Bloomberg Faculty of Nursing, University of Toronto, Toronto, Ontario, Canada; Provincial Centre of Weaning Excellence/Prolonged Ventilation Weaning Centre, Toronto East General Hospital, Toronto, Ontario, Canada; Mount Sinai Hospital and the Li Ka Shing Knowledge Institute, St Michael's Hospital, Toronto, Ontario, Canada.
Purpose:
To inform development of educational tools, we sought to identify initial ventilator settings and monitoring targets for 3 scenarios.
Method:
A survey was e-mailed to Canadian Society of Respiratory Therapists members with 2 reminders in March/April 2011.
Results:
Total evaluable surveys were 363. More participants selected pressure as opposed to volume ventilation for acute respiratory distress syndrome (ARDS; 77%) than for chronic obstructive pulmonary disease (COPD; 50%) and postoperative ventilation (32%; P < .001). Mean tidal volume was lower for ARDS than for COPD and postoperative ventilation (5.7, 6.9, and 7.2 mL/kg, respectively; P < .001). Maximum acceptable plateau pressures were highest for ARDS (30 cm H2O vs 29 cm H2O [COPD] and 27 cm H2O [postoperative], P < .001). Initial positive expiratory end pressure (12 cm H2O vs 7 cm H2O vs 5 cm H2O) and fraction of inspired oxygen (Fio2; 1.0 vs 0.5 vs 0.3) were also higher for ARDS (both P < .001); however, only 8% selected a positive expiratory end pressure/Fio2 combination as recommended by ARDSnet. Values of oxygen saturation as measured by pulse oximetry of 97% (ARDS) and 94% (COPD and postoperative) were considered appropriate for Fio2 reduction. The lowest pH was 7.28 vs 7.23 vs 7.26; the highest pH was 7.46 vs 7.44 vs 7.46 (P < .001). Partial pressure of carbon dioxide (arterial) of 51 mm Hg (postoperative) to 65 mm Hg (ARDS) was considered acceptable.
Conclusion:
Lung protective ventilation was favored, yet distinct differences in ventilator settings were evident. Monitoring targets suggested relatively conservative practices for Fio2 reduction but an understanding of permissive hypercapnia.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...