Related Experiment Video
Updated: May 4, 2026

Biotribological Testing and Analysis of Articular Cartilage Sliding against Metal for Implants
Published on: May 14, 2020
Use of bearings with integrated ceramic insert in cementless total hip arthroplasty – a preliminary report
Ireneusz Kotela1, Jacek Lorkowski1, Witold Sikorski1
1Department of Orthopaedic and Traumatology, Central Clinical Hospital of Ministry of Interior, Warsaw, Poland.
Background:
Ceramic-on-ceramic articulation presents advancement in the development modern of hip prostheses. It is particularly important for young patients, in whom complications related with polyethylene damages and metalosis pose a serious clinical problem due to the long period of implant functioning. The aim of this study was to assess the effect of total cementless hip replacement using an implant with a ceramic insert embedded in a metal cup and large prosthetic head constituting a ceramic-on-ceramic system in patients with hip osteoarthritis.
Material And Methods:
During years 2012-2013 there were 26 total hip replacements in 24 patients with use of integrated ceramic cup at Department of Orthopedic and Traumatology of the Central Clinical Hospital of Ministry of Interior, Warsaw. We assessed clinical and radiological outcomes of this procedure using HHS (Harris Hip Score), WOMAC (The Western Ontario and McMaster Universities Arthritis Index) and NRS (Numeric Rating Scale) scores.
Results:
In our study group patients presented with a significant degree of improvement in passive range of motion in the hip joint and no postoperative complications were noted. Significant statistical improvement was noted after surgery in each of the following scales HHS (50.84 vs. 87.16), WOMAC (51.01 vs. 91.88) and NRS (6.8 vs. 0.45). There were no signs of early or radiological evidence of loosening and implant migration among our patients.
Conclusions:
Cementless total hip arthroplasty using an acetabular component with a ceramic insert embedded in metal and a large prosthetic head (a ceramic-on-ceramic system) is an effective and a noteworthy method of treatment of hip osteoarthritis in young people.
Related Concept Videos
Pivot Bearings
A pivot bearing is a specialized type of bearing designed to support axial loads on a rotating shaft. The bearing surface, or the pivot, is positioned at the end of a shaft to support the axial thrust. The pivot may...
Journal Bearings
To better understand the concept of journal bearings, consider a rope winch with dry or...