Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Noninvasive measurements of hemodynamic transition directly after birth
Jeroen J van Vonderen1, Arno A W Roest2, Melissa L Siew3
1Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, The Netherlands.
Background:
Cardiac output depends on stroke volume and heart rate (HR). Only HR is used to monitor hemodynamic transition.
Methods:
In 24 term newborns born via cesarean section, HR and preductal blood pressure (BP) were measured. Also, using echocardiography, left ventricular dimensions and (Doppler derived) left ventricular output (LVO) were examined at 2, 5, and 10 min after birth.
Results:
Mean (SD) HR and BP did not change with time (mean HR: 157 (21) bpm at 2 min, 154 (17) bpm at 5 min, and 155 (14) bpm at 10 min; mean BP: 51.2 (15.4) mm Hg at 2 min, 50.5 (11.7) mm Hg at 5 min, and 49.6 (9.5) mm Hg at 10 min). Left ventricular end-diastolic diameter increased from 2 to 5 min (14.3 (1.3) vs. 16.3 (1.7) mm; P < 0.001) and stabilized at 10 min (16.7 (1.4) mm). LVO increased between 2 and 5 min (151 (47) vs. 203 (55) ml/kg/min; P < 0.001) and stabilized at 10 min (201 (45) ml/kg/min). LVO increase was associated with rise in left ventricular stroke volume (r = 0.94; P < 0.001), not with rise in HR (r = 0.37; P value not significant).
Conclusion:
Left ventricular dimensions and LVO significantly increased the first 5 min after birth and stabilized at 10 min, whereas BP remained stable. LVO and left ventricular dimension increase are presumably due to increasing left ventricular preload resulting from pulmonary blood flow and ductal shunting increase.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...