Related Experiment Video
Updated: May 4, 2026

Non-Invasive PET/MR Imaging in an Orthotopic Mouse Model of Hepatocellular Carcinoma
Published on: August 31, 2022
Protocol requirements and diagnostic value of PET/MR imaging for liver metastasis detection
Caecilia S Reiner1, Paul Stolzmann, Lars Husmann
1Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
Purpose:
To compare the accuracy of PET/MR imaging with that of FDG PET/CT and to determine the MR sequences necessary for the detection of liver metastasis using a trimodality PET/CT/MR set-up.
Methods:
Included in this single-centre IRB-approved study were 55 patients (22 women, age 61 ± 11 years) with suspected liver metastases from gastrointestinal cancer. Imaging using a trimodality PET/CT/MR set-up (time-of-flight PET/CT and 3-T whole-body MR imager) comprised PET, low-dose CT, contrast-enhanced (CE) CT of the abdomen, and MR with T1-W/T2-W, diffusion-weighted (DWI), and dynamic CE imaging. Two readers evaluated the following image sets for liver metastasis: PET/CT (set A), PET/CECT (B), PET/MR including T1-W/T2-W (C), T1-W/T2-W with either DWI (D) or CE imaging (E), and a combination (F). The accuracy of each image set was determined by receiver-operating characteristic analysis using image set B as the standard of reference.
Results:
Of 120 liver lesions in 21/55 patients (38%), 79 (66%) were considered malignant, and 63/79 (80%) showed abnormal FDG uptake. Accuracies were 0.937 (95% CI 89.5 - 97.9%) for image set A, 1.00 (95% CI 99.9 - 100.0%) for set C, 0.998 (95% CI 99.4 - 100.0%) for set D, 0.997 (95% CI 99.3 - 100.0%) for set E, and 0.995 (95% CI 99.0 - 100.0%) for set F. Differences were significant for image sets D - F (P < 0.05) when including lesions without abnormal FDG uptake. As shown by follow-up imaging after 50 - 177 days, the use of image sets D and both sets E and F led to the detection of metastases in one and three patients, respectively, and further metastases in the contralateral lobe in two patients negative on PET/CECT (P = 0.06).
Conclusion:
PET/MR imaging with T1-W/T2-W sequences results in similar diagnostic accuracy for the detection of liver metastases to PET/CECT. To significantly improve the characterization of liver lesions, we recommend the use of dynamic CE imaging sequences. PET/MR imaging has a diagnostic impact on clinical decision making.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Magnetic Resonance Imaging