Indocyanine green: photosensitizer or chromophore? Still a debate

Camille Giraudeau, Albert Moussaron, Aurelie Stallivieri

  • 1INSERM U703, Institut Hippocrate 152, rue du Dr. Yersin, 59120 LOOS France. serge.mordon@inserm.fr.

Current Medicinal Chemistry
|December 20, 2013
PubMed

Indocyanine green (ICG) is a water-soluble anionic tricarbocyanine dye developed during the Second World War that was first approved for clinical use in humans in 1956. The main features of ICG that make it suitable for bioimaging applications are its near infrared absorption and its fluorescence. Although ICG is mainly used for its fluorescence emission properties, it has also been hypothesized that it can serve as a photosensitizer for photodynamic therapy applications, eliciting cytotoxic effects both in vitro and in vivo when used in combination with light at wavelengths in the region of 800-830 nm. Moreover, ICG can be used for hyperthermia of enhanced-photocoagulation of blood vessels treatment. In this paper we have gathered all the available data concerning the use of ICG for different treatments.

Related Concept Videos

Channel Rhodopsins01:11

Channel Rhodopsins

Most organisms use photoreceptors to sense and respond to light. Examples of photoreceptors include bacteriorhodopsins and bacteriophytochromes in some bacteria, phytochromes in plants, and rhodopsins in the photoreceptor cells of the vertebral retina. The light-sensitive property of these receptors is because of the bound chromophores, such as bilin in the phytochromes and retinal in the rhodopsins.
Rhodopsins belong to the family of cell surface proteins called G-protein coupled receptors,...
2.5K
The Photochemical Reaction Center01:29

The Photochemical Reaction Center

Reaction centers are pigment-protein complexes that initiate energy conversion from photons to chemical entities. Therefore, photochemical reaction center is a more appropriate term that describes these complexes. The Nobel laureates Robert Emerson and William Arnold provided the first experimental evidence of photochemical reaction centers by demonstrating the participation of nearly 2,500 chlorophyll molecules for the release of just one molecule of oxygen. Despite thousands of photosynthetic...
4.4K
Fixation and Sectioning01:03

Fixation and Sectioning

Two basic types of preparation are used to visualize specimens with a light microscope: wet mounts and fixed specimens.
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
6.0K
Photoreceptors and Visual Pathways01:22

Photoreceptors and Visual Pathways

At the molecular level, visual signals trigger transformations in photopigment molecules, resulting in changes in the photoreceptor cell's membrane potential. The photon's energy level is denoted by its wavelength, with each specific wavelength of visible light associated with a distinct color. The spectral range of visible light, classified as electromagnetic radiation, spans from 380 to 720 nm. Electromagnetic radiation wavelengths exceeding 720 nm fall under the infrared category,...
8.5K
Color Vision01:24

Color Vision

Color perception begins in the retina, the light-sensitive layer at the back of the eye. Two main theories explain how colors are seen: the trichromatic theory and the opponent-process theory. The trichromatic theory, proposed by Thomas Young in 1802 and extended by Hermann von Helmholtz in 1852, suggests that color vision is based on three types of cone receptors in the retina. These cones are sensitive to different but overlapping ranges of wavelengths corresponding to red, blue, and green.
2.0K
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.3K