Orbital Cysticercosis: Comparing Multi-Slice CT and Steady State MR to Identify Scolex
S Govindappa Srikanth1, K Nagarajan, P N Jayakumar
1National Institute of Mental Health and Neurosciences; Bangalore, Karnataka, India - sgsrikanth@yahoo.com.
Detecting the scolex is key for diagnosing orbital cysticercosis. This study compared multi-slice CT and 3D steady-state MR imaging, finding both effective for identifying the scolex in orbital cysticercosis cases.
Area of Science:
- Ophthalmology
- Radiology
- Infectious Diseases
Background:
- Orbital cysticercosis, common in endemic regions, involves ocular and extraocular structures.
- The presence of a scolex is the definitive diagnostic marker for cysticercosis.
Purpose of the Study:
- To compare the efficacy of multi-slice computed tomography (CT) and 3D steady-state magnetic resonance (MR) imaging in identifying the scolex in orbital cysticercosis.
Main Methods:
- Three patients with orbital cysticercosis (one ocular, two extra-ocular) underwent imaging.
- Imaging techniques included multi-slice CT with thin coronal and sagittal reformations and a 3D steady-state MR sequence (CISS 3D).
Main Results:
- Both multi-slice CT and 3D steady-state MR imaging were utilized to visualize the scolex in orbital cysticercosis.
- The study included patients with both ocular and extra-ocular involvement.
Conclusions:
- Both multi-slice CT and 3D steady-state MR imaging demonstrate capability in identifying the scolex in orbital cysticercosis.
- Further research may elucidate the specific advantages of each modality for orbital cysticercosis diagnosis.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Urologic Endoscopic Procedure: Cystoscopic Examination
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...