Related Experiment Video
Updated: May 4, 2026

An Implantable System For Chronic In Vivo Electromyography
Published on: April 21, 2020
Clinical application of the Provox NiD voice prosthesis: a longitudinal study
Jan S Lewin1, Martha A Portwood, Yijia Wang
1Department of Head and Neck Surgery, University of Texas MD Anderson Cancer Center, Houston, Texas, U.S.A.
Objectives/Hypothesis:
To evaluate the indications, complications, and device life of the Provox NiD in a large cohort at a tertiary US cancer center.
Study Design:
Longitudinal retrospective cohort study.
Methods:
We reviewed the records of patients who used the NiD prosthesis (2005-2011) for general indicators, device life, and complications.
Results:
One hundred eighty-six patients who used the NiD were included (median follow-up: 21.4 months). The NiD was placed at initial fit in 41 (22%) patients, whereas 145 (78%) tried an NiD after using another type of prosthesis. Most patients used the NiD similarly to an indwelling device. Median NiD device life was significantly longer than that of other nonindwelling prostheses (45 vs. 29 days, P=.0061), and did not significantly differ from that of standard indwelling devices (45 vs. 50 days, P=.4263). Thirty-eight percent (71 of 189) of NiD users had a history of early leakage (<8 weeks) using a different prosthesis before trying the NiD. Among patients with a pre-existing history of early leakage, almost 90% of NiD prostheses outperformed the device life of other products.
Conclusions:
The NiD prosthesis offers satisfactory device life on a par with indwelling prostheses in our cohort of NiD users. Coupled with favorable published airflow characteristics and satisfactory tracheoesophageal voice, these data suggest that the NiD offers a durable, low-cost prosthetic alternative in contemporary practice. A unique indication for NiD may be improved device life in some patients with a history of early leakage.
Level Of Evidence:
4.
Related Concept Videos
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...