Managed ventricular pacing facilitating atrioventricular nodal reentrant tachycardia
Daniel R Frisch1, Anand S Kenia, Paul Walinsky
1Thomas Jefferson University Hospital, Jefferson Heart Institute, Philadelphia, Pennsylvania.
Pacing and Clinical Electrophysiology : PACE
|December 21, 2013
Abstract
No abstract available in PubMed .
More Related Videos
Related Concept Videos
Ventilatory Modes
2.3K
Mechanical ventilators are life-saving devices that support or replace spontaneous breathing. They deliver breaths to patients through varying methods known as ventilator modes. Understanding these modes is critical for healthcare providers managing patients with respiratory failure.
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
2.3K
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
1.2K
Arrhythmia is a condition characterized by an irregular heart rhythm, with ECG changes that differ based on its origin and nature. The types of arrhythmias discussed below include atrial, junctional, and ventricular arrhythmias.Atrial ArrhythmiasPremature Atrial Complexes (PACs): PACs are early atrial beats caused by stress, caffeine, alcohol, electrolyte imbalances, hypoxia, hyperthyroidism, or certain medications (e.g., bronchodilators and decongestants). The ECG shows early P waves with an...
1.2K
Dysrhythmias VI: Management of Dysrhythmias
597
Dysrhythmia management involves a multifaceted approach, incorporating pharmacological treatments, medical procedures, surgical interventions, lifestyle modifications, and patient education.Pharmacological ManagementAntiarrhythmic Drugs:Class I (Sodium Channel Blockers): This class includes quinidine and procainamide, which reduce the speed of impulse conduction in the heart, stabilize the cardiac membrane, and control arrhythmias. Quinidine and procainamide are Class IA agents that prolong the...
597
Disturbances in Heart Rhythm
5.3K
Arrhythmia or dysrhythmia refers to an abnormal heart rhythm caused by a defect in the heart's conduction system. It can cause the heart to beat irregularly, too quickly, or too slowly, leading to symptoms like chest pain, shortness of breath, and fainting. Factors such as stress, caffeine, alcohol, nicotine, cocaine, certain drugs, congenital defects, diseases, and electrolyte abnormalities can trigger arrhythmias.
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
5.3K
Dysrhythmias II: Classification of Tachyarrhythmias
735
Tachyarrhythmias are a type of dysrhythmia where the heart rate exceeds 100 beats per minute. Here are some common types of tachyarrhythmias:Sinus TachycardiaSinus tachycardia originates from increased impulses from the sinus node, leading to an elevated heart rate. It is often triggered by stress, fever, or exercise.Patients may experience palpitations, a sensation of a racing heart, dizziness, and chest discomfort.Causes and Risk Factors: Common causes include physical exertion, emotional...
735
Conduction System of the Heart
13.5K
Autorhythmicity is a term that refers to the heart's inherent ability to generate electrical signals and instigate muscle contractions. This self-regulating conduction system within the heart consists of two key components: the pacemaker cells and specialized conducting cells.
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
13.5K


