Clinical outcomes after bilateral implantation of an apodized +3.0 D toric diffractive multifocal intraocular lens
José F Alfonso1, Michael Knorz1, Luis Fernandez-Vega1
1From the Instituto Oftalmológico Fernandez-Vega (Alfonso, Fernandez-Vega), Astúrias, Spain; the Department of Ophthalmology (Titke, Kohnen), Goethe University, Frankfurt, and the FreeVis LASIK Zentrum Universitatsklinikum (Knorz), Mannheim, Germany; the Instituto Oftalmológico IUMO CA (Rincon) and Centro Medico Docente la Trinidad (Suarez), Caracas, Venezuela.
Purpose:
To assess visual outcomes after bilateral implantation of an apodized +3.0 diopter (D) addition power toric diffractive multifocal intraocular lens (IOL).
Setting:
Five study sites in Europe and South America.
Design:
Cohort study.
Methods:
Patients had bilateral implantation of the AcrySof(®) IQ ReSTOR(®)+3.0 D toric multifocal IOL. Inclusion criteria were age from 21 to 70 years, need for bilateral cataract extraction or refractive lens exchange, and regular corneal astigmatism from 0.75 to 2.5 D. Six-month evaluations included spherical equivalent (SE), refractive and corneal cylinder, visual acuity at various distances, defocus testing, reading speed, and IOL rotation.
Results:
Forty-four of 49 patients completed the 6-month visit. The mean SE (88 eyes) was 0.09 D ± 0.49 (SD) at 6 months (± 1.00 D in 95.2%). The mean refractive cylinder decreased from 1.07 ± 0.71 D to 0.33 ± 0.44 D (≤ 0.50 D in 78.6% and ≤ 1.00 D in 92.9%). The mean binocular uncorrected visual acuity was 0.04 ± 0.08 logMAR at preferred near (≈ 39 cm), 0.07 ± 0.09 logMAR at 40 cm, 0.09 ± 0.11 logMAR at 60 cm, and 0.05 ± 0.10 logMAR at 4 m. The mean corrected reading speed increased from 125.43 ± 33.58 words per minute (wpm) to 132.68 ± 23.69 wpm. The mean IOL rotation was 2.20 ± 4.34 degrees.
Conclusion:
Six months after implantation of the toric multifocal IOL, patients had significantly reduced SE and refractive cylinder, good visual acuity across distances, increased reading speed, and minimal IOL rotation.
More Related Videos
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment