Related Experiment Video
Updated: Jan 29, 2026

Estimating Vestibular Perceptual Thresholds Using a Six-Degree-Of-Freedom Motion Platform
Published on: August 4, 2022
Defibrillation threshold: a simple and quantitative estimate of the ability to defibrillate
Abstract:
It has recently been shown that the probability of successful defibrillation as a function of energy has a sigmoidal dose-response relationship. Determination of a defibrillation "dose-response curve" is time consuming and requires multiple defibrillation attempts. On the other hand, determination of a defibrillation threshold is achieved rapidly and would be better suited to study the effect of interventions on the ability to defibrillate patients. We assessed the relationship of defibrillation threshold to the defibrillation "dose-response curve" in twelve open chest, halothane anesthetized pigs. Ventricular fibrillation was induced electrically, and defibrillation was attempted by passing sequential pulse shocks through an indwelling catheter and plaque electrodes. Defibrillation threshold was determined by decreasing the stored voltage of the initial shock until it failed to defibrillate the heart. Five different stored voltage levels distributed around defibrillation threshold were then randomly administered, six times for each level. A "dose-response curve" was obtained for each animal. Defibrillation threshold superimposed on the "dose-response curve" at 76 +/- 7.2 percent (mean +/- SEM) defibrillation success. Energy delivered at 1.5 times average defibrillation threshold was predicted to achieve 100 percent defibrillation success for a single shock in all animals. We conclude that defibrillation threshold provides a simple and quantitative estimate of the ability to defibrillate with a predictable relationship to the "dose-response curve."
More Related Videos
07:12Assessment of Sensory Thresholds in Dogs Using Mechanical and Hot Thermal Quantitative Sensory Testing
Published on: October 26, 2021
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Estimation of k and VD of Aminoglycosides
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Estimation of the Physical Quantities
Simple Pendulum
The period of a simple pendulum depends on two factors: its length and the acceleration due to gravity. The period is completely independent of any other factors, such as mass or maximum displacement. For small displacements, a pendulum is...
Simple Trusses
The most basic planar truss is a simple truss with three members arranged in a triangular formation. This triangular truss is inherently stable and rigid due to its geometry, making it an ideal starting point for creating more...
Estimating Population Standard Deviation