Related Experiment Video
Updated: Aug 16, 2026

A Microfluidic Flow Chamber Model for Platelet Transfusion and Hemostasis Measures Platelet Deposition and Fibrin Formation in Real-time
Published on: February 14, 2017
Heterogeneity of platelet secretion in response to thrombin demonstrated by fluorescence flow cytometry
Platelet membrane changes that accompany in vivo activation may be difficult to detect if only a small fraction of circulating platelets has undergone secretion. This study describes an approach to that problem by using a method to measure the number of molecules of fluorescein-labeled antibody bound to individual platelets by flow cytometry. The platelet response to different concentrations of thrombin was determined by measuring the binding of a monoclonal antibody (S12) to GMP-140, an alpha-granule membrane protein that becomes exposed on the platelet surface during alpha-granule secretion. Unstimulated platelets bound a mean of 1,120 molecules of S12 per cell, and 93% of platelets bound less than 2,000 molecules. Platelet stimulation by 0.25 U/mL thrombin caused maximum S12 binding with a mean of 7,529 molecules per cell. Even at low concentrations of thrombin (0.025 U/mL), 5% of platelets were maximally activated, binding over 7,000 molecules of S12 per cell. Conversely, at 0.25 U/mL thrombin, 13% of platelets continued to bind less than 2,000 molecules of S12 per cell. A mixture of as little as 5% thrombin-activated platelets with unstimulated platelets could be detected by this method. Therefore flow cytometry offers an important tool for investigating patients who may have circulating activated platelets as part of a disorder predisposing to thrombosis or hemorrhage.
Platelet membrane changes that accompany in vivo activation may be difficult to detect if only a small fraction of circulating platelets has undergone secretion. This study describes an approach to that problem by using a method to measure the number of molecules of fluorescein-labeled antibody bound to individual platelets by flow cytometry. The platelet response to different concentrations of thrombin was determined by measuring the binding of a monoclonal antibody (S12) to GMP-140, an alpha-granule membrane protein that becomes exposed on the platelet surface during alpha-granule secretion. Unstimulated platelets bound a mean of 1,120 molecules of S12 per cell, and 93% of platelets bound less than 2,000 molecules. Platelet stimulation by 0.25 U/mL thrombin caused maximum S12 binding with a mean of 7,529 molecules per cell. Even at low concentrations of thrombin (0.025 U/mL), 5% of platelets were maximally activated, binding over 7,000 molecules of S12 per cell. Conversely, at 0.25 U/mL thrombin, 13% of platelets continued to bind less than 2,000 molecules of S12 per cell. A mixture of as little as 5% thrombin-activated platelets with unstimulated platelets could be detected by this method. Therefore flow cytometry offers an important tool for investigating patients who may have circulating activated platelets as part of a disorder predisposing to thrombosis or hemorrhage.

