Comprehensive two-dimensional GC for the analysis of low-molecular-weight oxygenates in three different matrices from
Wonga Hexana1, Piet De Coning, Samuel Jali
1Analytical Science Group, Analytical Solutions Department, Research & Development, Sasol Technology (Pty) Ltd, Sasolburg, South Africa.
Abstract:
A method using comprehensive (2) DGC with flame ionisation detection was developed to quantify 17 low-molecular-weight oxygenates in three different matrices, namely water, oil and gas, using a single calibration. The method was required for the pilot-plant experiments of a chemical process unit. From an analytical perspective, the first task was to find a suitable analytical method with sufficient selectivity and sensitivity to analyse the selected oxygenates at low levels in the presence of high levels of hydrocarbons. The second was the accurate quantitation of oxygenates in the water, oil and gas fractions, using the same instrument and calibration. Both these requirements were met by using comprehensive (2) DGC in the inverse configuration and calibrating the detector with the number of moles injected versus response. The method was successfully applied for the characterisation of the reactor product stream of the chemical process unit and made it possible to determine the fate of the selected oxygenates after passing through the reactor. The development of the method and some of the results are described in this paper.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:22Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...