Correlation of cardiac output and sevoflurane required to maintain anesthetic depth targeted with entropy index
Andrei E Bautin1, Ann V Siganevich, Elena Y Malaya
1Department of Anesthesiology, Almazov Federal Heart, Blood and Endocrinology Centre, Saint Petersburg, Russia.
Aims And Objectives:
We investigated the correlation of reduced cardiac output on required sevoflurane to maintain targeted anesthesia depth.
Materials And Methods:
36 patients undergoing coronary artery bypass grafting with cardiopulmonary bypass were prospectively included in the study. Inspired sevoflurane concentration was adjusted to ensure state entropy index < 40. Analgesia was provided by either boluses of fentanyl 200 μg or continuous infusion of fentanyl 5 μg/kg/h; the total dose of fentanyl administered in the patients was not different (fentanyl boluses 6.5 ± 0.3 μg/kg/h vs. fentanyl infusion 5 μg/kg/h). Cardiac-index (CI), end tidal sevoflurane (ETsev) and entropy index were measured simultaneously at 1-5 min after sternotomy, during internal mammary artery harvesting and during pericardiotomy. 108 sets of variables (entropy index, ETsev, CI) were recorded from 36 subjects at three time points; 13 sets were excluded due to technical drawbacks in measurements. 95 data sets were eligible for analysis. Sixty-five data sets measured in patients with target state entropy index were analyzed to establish the relationship between CI and ETsev.
Results:
We did not find a linear correlation between ETsev and CI in patients with target entropy index (correlation coefficient = 0.18, P = 0.14). The ETsev necessary to maintain the target level of anesthesia was lower in patients with CI ≤ 2.2 l/min/m2 (1.15% ± 0.28%) than patients with CI > 2.2 l/min/m2 (1.37% ± 0.31%), P = 0.01.
Conclusion:
Relationship between CI and ETsev required for maintaining target level of anesthesia is non-linear. Patients with CI ≤ 2.2 l/min/m2 need lower levels of the ETsev for maintenance of the target anesthesia at an entropy index < 40.
More Related Videos
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
08:49Assessing Changes in Volatile General Anesthetic Sensitivity of Mice after Local or Systemic Pharmacological Intervention
Published on: October 16, 2013
Related Concept Videos
Inhalational Anesthetics: Overview
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Stages of General Anesthesia
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
