Related Experiment Video
Updated: May 4, 2026

Application of an Amplitude-integrated EEG Monitor Cerebral Function Monitor to Neonates
Published on: September 6, 2017
Importance of Normal Values of CSF Parameters in Term Versus Preterm Neonates
Arijit Majumdar1, Angshuman Jana1, Anirban Jana1
1Department of Pathology and Bio Chemistry, Dr. Bidhan Chandra Roy Post Graduate Institute of Pediatric Sciences, Kolkata, West Bengal, India.
Background:
Evaluation of the cerebrospinal fluid (CSF) white blood cell (WBC) count and glucose and protein concentrations is used to assess the probability of the presence of central nervous system (CNS) infection. Although normal values are well established for CSF cell counts and protein and glucose contents in children and adults, this is not the case for neonates.
Aims:
The purpose of this study was to evaluate the composition of noninfected CSF obtained by nontraumatic lumbar puncture in neonates (age<28 days), specifically distinguishing CSF profiles of those term babies compared with those premature infants.
Materials And Methods:
The CSF samples obtained by lumbar puncture from 120 neonates were examined by routine procedures.
Results:
By comparing CSF parameters between term gestation neonate group with premature neonate one, nontraumatic puncture, there was no statistically significant difference (P<0.05) in the mean WBC (P=0.6). The mean protein concentration was significantly greater in those premature neonates (P<0.04). The mean glucose concentration was also analogous in both groups (P=0.5).
Conclusion:
The CSF profile, like any other laboratory determination, should be evaluated within the clinical context of the individual case.