Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume
C Slagt1, I Malagon, A B J Groeneveld
1Department of Anaesthesiology and Intensive Care, Zaans Medical Centre, Koningin Julianaplein 58, 1502 DV Zaandam, The Netherlands.
Unlabelled:
The FloTrac/Vigileo™, introduced in 2005, uses arterial pressure waveform analysis to calculate cardiac output (CO) and stroke volume variation (SVV) without external calibration. The aim of this systematic review is to evaluate the performance of the system. Sixty-five full manuscripts on validation of CO measurements in humans, published in English, were retrieved; these included 2234 patients and 44,592 observations.
Results:
have been analysed according to underlying patient conditions, that is, general critical illness and surgery as normodynamic conditions, cardiac and (post)cardiac surgery as hypodynamic conditions, and liver surgery and sepsis as hyperdynamic conditions, and subsequently released software versions. Eight studies compared SVV with other dynamic indices. CO, bias, precision, %error, correlation, and concordance differed among underlying conditions, subsequent software versions, and their interactions, suggesting increasing accuracy and precision, particularly in hypo- and normodynamic conditions. The bias and the trending capacity remain dependent on (changes in) vascular tone with most recent software. The SVV only moderately agreed with other dynamic indices, although it was helpful in predicting fluid responsiveness in 85% of studies addressing this. Since its introduction, the performance of uncalibrated FloTrac/Vigileo™ has improved particularly in hypo- and normodynamic conditions. A %error at or below 30% with most recent software allows sufficiently accurate and precise CO measurements and trending for routine clinical use in normo- and hypodynamic conditions, in the absence of large changes in vascular tone. The SVV may usefully supplement these measurements.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...