Related Experiment Video
Updated: May 4, 2026

Production and Testing of Moisture Behavior and Thermal Properties of Rapeseed Straw and Ganoderma resinaceum Mycelium Bio-Composites
Published on: September 5, 2025
Comparative Evaluation of Dimensional Accuracy and Tensile Strength of a Type IV Gypsum Using Microwave and Air
Anuraag Sharma1, Manoj Shetty2, Chethan Hegde2
1Department of Prosthodontics, Maharana Pratap Dental College, Kanpur, India.
Abstract:
To evaluate dimensional accuracy and tensile strength of a type IV gypsum product, at different time intervals, dried in air or a microwave oven. Eighty specimens prepared from a cylindrical mould were used for measuring tensile strength (group A). Twenty specimens from a master die mould were used for determining dimensional accuracy (group B). In group A, 40 specimens were dried in open air at room temperature (A1). The other 40 were removed after 30 min and air dried for 20 min. These were subjected to microwave oven drying for 5 min (A2). Ten specimens each were tested under diametral compression at each of the following time periods: 1, 2, 4 and 24 h after drying. In group B, ten specimens were dried in open air at room temperature (B1). Ten specimens were removed from the mould after 30 min and air dried for 20 min. These were then dried in a microwave oven for 5 min (B2). The data was statistically analyzed using students unpaired "t" test. At all time intervals, diametral tensile strength (DTS) values for specimens dried in microwave oven were significantly higher than for those dried in open air. There were no significant differences between the dimensional accuracy of the two groups. In this study, microwave oven drying had a positive effect on the DTS of a type IV gypsum and the microwave oven dried specimens were as accurate as the air dried specimens over the same time period.
More Related Videos
09:54Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
11:38Environmentally-controlled Microtensile Testing of Mechanically-adaptive Polymer Nanocomposites for ex vivo Characterization
Published on: August 20, 2013
Related Concept Videos
Mortar Properties
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Measurement of Air Content in Concrete
The pressure method,...
Fineness of Cement
Direct...
Moisture Content and Bulking of Aggregate
When aggregates are exposed to rain or sit in stockpiles, they absorb moisture, which must be...
Testing Water Quality