Chlorophyll fluorescence transients from the diatom Phaeodactylum tricornutum: relative rates of cyclic

L Caron1, C Berkaloff, J C Duval

  • 1Laboratoire de Biologie végétale, Université de Perpignan, Avenue de Villeneuve, F-66025, Perpignan Cedex, France.

Photosynthesis Research
|January 18, 2014
PubMed

Related Concept Videos

Channel Rhodopsins01:11

Channel Rhodopsins

Most organisms use photoreceptors to sense and respond to light. Examples of photoreceptors include bacteriorhodopsins and bacteriophytochromes in some bacteria, phytochromes in plants, and rhodopsins in the photoreceptor cells of the vertebral retina. The light-sensitive property of these receptors is because of the bound chromophores, such as bilin in the phytochromes and retinal in the rhodopsins.
Rhodopsins belong to the family of cell surface proteins called G-protein coupled receptors,...
2.5K
The Z-Scheme of Electron Transport in Photosynthesis01:34

The Z-Scheme of Electron Transport in Photosynthesis

The light reactions of photosynthesis assume a linear flow of electrons from water to NADP+. During this process, light energy drives the splitting of water molecules to produce oxygen. However, oxidation of water molecules is a thermodynamically unfavorable reaction and requires a strong oxidizing agent. This is accomplished by the first product of light reactions: oxidized P680 (or P680+), the most powerful oxidizing agent known in biology. The oxidized P680 that acquires an electron from the...
12.6K
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
1.9K
Protein Dynamics in Living Cells01:19

Protein Dynamics in Living Cells

Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
1.9K
Photosystem I01:27

Photosystem I

Although structurally similar to photosystem II (PSII), photosystem I (PSI) is has a different electron supplier and electron acceptor.
Both these photosystems work in concert. An excited electron from PSII is relayed to PSI via an electron transport chain in the thylakoid membrane of the chloroplast, which is comprised of the carrier molecule plastoquinone, the dual-protein cytochrome complex, and plastocyanin. As electrons move between PSII and PSI, they lose energy and must be re-energized...
52.8K