Purpose:
To determine the refractive cylinder effect of rotating a toric intraocular lens (IOL) and identify the sources of refractive astigmatic surprise after toric IOL implantation.
Setting:
Private practice, Melbourne, Australia.
Design:
Experimental study.
Methods:
Vergence formulas using a standard reduced eye model were used to bring all lens powers to the corneal plane. Double-angle vector diagrams were then used to (1) determine the refractive cylinder effect of rotating a toric IOL and (2) show how the prevailing astigmatism and the various planning and surgical steps involved in implanting a toric IOL contribute to the postoperative manifest refractive cylinder.
Results:
An example calculation is given to illustrate the method.
Conclusions:
Refractive cylinder surprises can occur after toric IOL implantation. Understanding the causes enables surgeons to address contributory factors and choose an appropriate surgical method for managing individual cases of refractive cylinder surprise.
Financial Disclosure:
Dr. Alpins and Mr. Stamatelatos have a financial interest in the Assort software program used to support the planning and analysis of astigmatic correction. Dr. Ong is an employee of Assort.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Angle Closure Glaucoma: Treatment
Focusing of Light in the Eye
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...