Related Experiment Video
Updated: May 3, 2026

HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
LC-MS method for the simultaneous determination of six glucocorticoids in pharmaceutical formulations and counterfeit
Jessica Fiori1, Vincenza Andrisano2
1Department of Pharmacy and Biotechnology, University of Bologna, via Belmeloro 6, 40126 Bologna, Italy.
Abstract:
A screening method based on liquid chromatography-electrospray mass spectrometry for the simultaneous determination of six corticosteroids (betamethasone 17-valerate BM 17-V, beclomethasone BC, beclomethasone dipropionate BCDP, methylprednisolone MP, budesonide BD, flunisolide FN) was developed in order to control their illegal use in cosmetic and natural products. Indeed, despite corticosteroids are banned in cosmetics, counterfeit products might be present on the market, representing a health hazard. Therefore, effective analytical methods are required to rapidly screen over the counter products in health care shops for counterfeit corticosteroids. The analytical method involves the employment of a Waters Synergy C18 column (150mm×2.0mm I.D.) by using the following mobile phase: A (0.1% formic acid in acetonitrile), B (0.1% formic acid in water) in a linear gradient (from A-B 25:75, v/v to A-B 95:5, v/v in 30min) at the flow rate of 0.3mL/min. The detection was performed with an ion trap (IT) mass spectrometer in positive polarity, total ion current (TIC) and tandem mass modalities for qualitative purpose; single ion monitoring (SIM) mode was used for quantitative analysis on the ESI generated most abundant ion for each steroid. The method was fully validated in terms of precision, detection and quantification limits, linearity, recovery, and it was applied to the identification and quantification of corticosteroids in pharmaceutical formulations and cosmetic products. The mean recovery of BM 17-V, BC, BCDP, MP, BD and FN were found to be 101.3, 101.5, 98.8, 98.9, 98.1, 99.0%, respectively. Limits of quantitation (LOQ) were comprised in the range 29-95ng/mL. To the best of our knowledge, for the first time this mix of glucocorticoids were simultaneously determined in cosmetic products by using a fully validated method. BMV, in its two isomeric forms BM 17-V and BM 21-V, was found to be illegally present in one cream sample (A) with the total concentration level of 0.036% (w/w).
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....