Determination of allergenic hydroperoxides in essential oils using gas chromatography with electron ionization mass
Johanna Rudbäck1, Ahmed Ramzy, Ann-Therese Karlberg
1Department of Chemistry and Molecular Biology, Dermatochemistry and Skin Allergy, University of Gothenburg, Gothenburg, Sweden.
Abstract:
Fragrance monoterpenes are widely used commercially due to their pleasant scent. In previous studies, we have shown that air-exposed monoterpenes form hydroperoxides that are strong skin sensitizers. Methods for detection and quantification of the hydroperoxides in essential oils and scented products are thus desirable. Due to thermolability and low UV absorbance, this is a complicated task. We have recently developed a sensitive LC-ESI-MS method, but with limited structural information and separation efficiency for positional isomers and stereoisomers. In the present study, we investigated derivatization with a trimethyl silyl reagent and subsequent GC with electron ionization MS for the determination of monoterpene hydroperoxides. All investigated monoterpene hydroperoxides could be chromatographed as thermostable trimethyl silyl derivatives and yielded the fragment m/z 89 ([OSi(CH3)3](+)) at a higher extent compared to corresponding alcohols. Limonene-2-hydroperoxide and four other hydroperoxide isomers of limonene were separated and detected in sweet orange oil autoxidized for two months. The concentration of limonene-2-hydroperoxide isomers was found to be 19 μg/mg in total. Also isomers of linalyl acetate hydroperoxide and linalool hydroperoxide were detected in autoxidized petitgrain oil (two months). The presented GC-MS method showed concentrations in the same order as previous LC-MS/MS analysis of the same type of oils.
More Related Videos
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Autoxidation of Ethers to Peroxides and Hydroperoxides
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...