Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

9.4K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
9.4K
X-ray Imaging01:24

X-ray Imaging

7.7K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
7.7K
X-ray Crystallography02:18

X-ray Crystallography

21.6K
The size of the unit cell and the arrangement of atoms in a crystal may be determined from measurements of the diffraction of X-rays by the crystal, termed X-ray crystallography.
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
21.6K
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

785
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
785

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Simultaneous hard x-ray Talbot phase and dark-field imaging in laser experiments at XFEL facilities.

The Review of scientific instruments·2025
Same author

A Conditional Generative Diffusion Model of Trabecular Bone with Tunable Microstructure.

Proceedings of SPIE--the International Society for Optical Engineering·2025
Same author

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources.

Optics express·2025
Same author

Exposure control at the first dark-field chest radiography demonstrator system.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2025
Same author

Finite element fracture load analysis and dark-field X-ray imaging of osteoporotic and healthy vertebrae in human lumbar spine specimens.

BMC musculoskeletal disorders·2025
Same author

Parity-dependent state transfer for direct entanglement generation.

Nature communications·2025
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

Related Experiment Video

Updated: May 3, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
10:39

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

Published on: October 11, 2016

9.1K

High energy x-ray phase contrast CT using glancing-angle grating interferometers.

A Sarapata1, J W Stayman2, M Finkenthal3

  • 1Department of Physics and Astronomy, Johns Hopkins University, Baltimore, Maryland 21218 and Department of Physics and Institute of Medical Engineering, Technische Universität München, 85748 Garching, Germany.

Medical Physics
|February 11, 2014
PubMed
Summary
This summary is machine-generated.

This study introduces a new x-ray phase contrast CT system using glancing-angle interferometry. It achieves high soft tissue contrast at doses comparable to conventional CT, offering a potentially complementary imaging tool.

More Related Videos

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Published on: February 21, 2017

9.0K
Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
09:00

Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography

Published on: September 29, 2019

12.0K

Related Experiment Videos

Last Updated: May 3, 2026

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
10:39

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

Published on: October 11, 2016

9.1K
Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
10:18

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography

Published on: February 21, 2017

9.0K
Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
09:00

Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography

Published on: September 29, 2019

12.0K

Area of Science:

  • Medical Imaging
  • Biomedical Engineering
  • X-ray Physics

Background:

  • Conventional absorption-based CT has limitations in soft tissue contrast.
  • X-ray phase contrast imaging offers potential for enhanced soft tissue visualization.
  • Developing clinically compatible phase contrast CT systems is an ongoing challenge.

Purpose of the Study:

  • To present initial progress toward a clinically compatible x-ray phase contrast CT system.
  • To evaluate the use of glancing-angle x-ray grating interferometry for soft tissue imaging.
  • To assess dose levels comparable to conventional CT.

Main Methods:

  • Performed DPC-CT scans of phantoms and soft tissues.
  • Compared high and low fringe visibility systems.
  • Evaluated phase stepping vs. sliding window interlaced scanning.
  • Studied phase image contrast dependence on dose using Monte Carlo simulations.

Main Results:

  • Achieved nearly 50% fringe visibility at 45 keV using a glancing angle interferometer.
  • Sliding window interlaced scanning improved SNR and CNR.
  • Obtained soft tissue images at doses (∼8 mGy) similar to conventional CT.
  • Demonstrated good soft tissue contrast for a human knee model.

Conclusions:

  • DPC-CT with glancing-angle interferometers offers improved soft tissue contrast at clinically compatible doses.
  • Further advancements in image processing and reconstruction are needed for full clinical compatibility.
  • The technique is best suited as a complementary tool to conventional CT for specific applications.