Related Experiment Video
Updated: May 3, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Comprehensive two-dimensional gas chromatography under high outlet pressure conditions: a new approach to correct the
Daniela Peroni1, Hans-Gerd Janssen2
1University of Amsterdam, van't Hoff Institute for Molecular Sciences, Analytical-Chemistry Group, P.O. Box 94157, 1090 GD Amsterdam, The Netherlands.
Abstract:
The typical column sets employed in comprehensive two-dimensional gas chromatography (GC × GC) suffer from the impossibility to fully exploit the efficiency of both dimensions simultaneously. Adding a restrictor at the end of the second dimension is a possible approach to adjust the linear velocity profile. Under these high outlet pressure conditions the second dimension becomes much slower while the effect on the primary column is limited. The gap in terms of optimum inlet pressures is thus reduced. A program written in Microsoft Excel was used to calculate the efficiencies of the two dimensions in GC × GC at different outlet pressures. A GC × GC set-up with a restrictor at the end of the second dimension column was successfully installed. Experiments proved that this is a possible way to have a better exploitation of the columns. The chromatograms obtained for a number of applications confirm that the separations achieved at elevated outlet pressure are more efficient than those obtained with the same column set under atmospheric outlet conditions. The price to pay is that the separations become considerably slower.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...