Related Experiment Video
Updated: May 3, 2026

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Gap measurement in posterior-stabilized total knee arthroplasty with or without a trial femoral component
Seiju Hayashi1, Yuji Murakami, Hiroyuki Inoue
1Department of Orthopaedic Surgery, Hiroshima Prefectural Hospital, 1-5-54, Ujinakanda, Minami-ku, Hiroshima, 734-8530, Japan, payakichi0213@hotmail.com.
Purpose:
To investigate the effects of a trial femoral component on the intraoperative joint gap and intraoperative joint gap kinematics throughout the range of knee motion in minimally invasive surgery-total knee arthroplasty (MIS-TKA) with the gap technique.
Materials And Methods:
A total of 103 patients [15 men (15 knees) and 89 women (89 knees)] aged 50-88 years (mean 74.8 years) who received MIS-TKA with the gap technique were included. The intraoperative joint gap differences (90° flexion gap distance minus 0° extension gap distance) with and without the trial femoral component were compared. Subsequently, the intraoperative joint gap kinematics at 0°, 45°, 90°, and 120° with the trial femoral component were investigated.
Results:
The intraoperative component gap difference (4.4 ± 2.7 mm) was larger than the estimated joint gap difference (1.2 ± 1.9 mm) (p < 0.01). The mean intraoperative component gap distances at 0°, 45°, 90°, and 120° of knee flexion were 14.7 ± 2.6, 19.0 ± 3.2, 19.2 ± 3.4, and 16.6 ± 3.3 mm, respectively. The intraoperative component gap distance increased significantly from 0° extension to 90° of knee flexion (p < 0.01), and then decreased significantly toward deep knee flexion at 120° (p < 0.01).
Conclusions:
The trial femoral component influenced the intraoperative gap measurements, and increased the intraoperative gap difference. The joint gap kinematics with the trial femoral component were not constant throughout the range of knee motion, even if the appropriate joint gaps in extension and flexion were achieved. For acquisition of constant stability throughout the knee motion, the present results should be taken into account by surgeons performing MIS-TKA with the gap technique.
More Related Videos
09:31Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022