Purpose:
Quality assurance (QA) phantoms for testing different image quality parameters in computed tomography (CT) are commercially available. Such phantoms are also used as reference for acceptance in the specifications of CT-scanners. The aim of this study was to analyze the characteristics of the most commonly used QA phantom in CT: Catphan 500/504/600.
Methods:
Nine different phantoms were scanned on the same day, on one CT-scanner with the same parameter settings. Interphantom variations in CT-number values, image uniformity and low contrast resolution were evaluated for the phantoms. Comparisons between manual image analysis and results obtained from the automatic evaluation software QAlite were performed.
Results:
Some interphantom variations were observed in the low contrast resolution and the CT-number modules of the phantoms. Depending on the chosen regulatory framework, the variations in CT-numbers can be interpreted as substantial. The homogenous modules were found more invariable. However, the automatic image analysis software QAlite measures image uniformity differently than recommended in international standards, and will not necessarily give results in agreement with these standards.
Conclusions:
It is important to consider the interphantom variations in relation to ones framework, and to be aware of which phantom is used to study CT-numbers and low contrast resolution for a specific scanner. Comparisons with predicted values from manual and acceptance values should be performed with care and consideration. If automatic software-based evaluations are to be used, users should be aware that large differences can exist for the image uniformity testing.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...