Ability to discriminate between healthy and low back pain sufferers using ultrasound during maximum lumbar extension
Antonio I Cuesta-Vargas1, Manuel González-Sánchez2
1IBIMA, Department of Physiotherapy, Faculty of Health Sciences, Andalucia Tech, University of Malaga, Malaga, Spain; School of Clinical Sciences, Faculty of Health, Queensland University of Technology, Brisbane, QLD, Australia.
Objective:
To analyze the ability to discriminate between healthy individuals and individuals with chronic nonspecific low back pain (CNLBP) by measuring the relation between patient-reported outcomes and objective clinical outcome measures of the erector spinae (ES) muscles using an ultrasound during maximal isometric lumbar extension.
Design:
Cross-sectional study with screening and diagnostic tests with no blinded comparison.
Setting:
University laboratory.
Participants:
Healthy individuals (n=33) and individuals with CNLBP (n=33).
Interventions:
Each subject performed an isometric lumbar extension. With the variables measured, a discriminate analysis was performed using a value ≥ 6 in the Roland and Morris disability questionnaire (RMDQ) as the grouping variable. Then, a logistic regression with the functional and architectural variables was performed. A new index was obtained from each subject value input in the discriminate multivariate analysis.
Main Outcome Measures:
Morphologic muscle variables of the ES muscle were measured through ultrasound images. The reliability of the measures was calculated through intraclass correlation coefficients (ICCs). The relation between patient-reported outcomes and objective clinical outcome measures was analyzed using a discriminate function from standardized values of the variables and an analysis of the reliability of the ultrasound measurement.
Results:
The reliability tests show an ICC value >.95 for morphologic and functional variables. The independent variables included in the analysis explained 42% (P=.003) of the dependent variable variance.
Conclusions:
The relation between objective variables (electromyography, thickness, pennation angle) and a subjective variable (RMDQ ≥ 6) and the capacity of this relation to identify CNLBP within a group of healthy subjects is moderate. These results should be considered by clinicians when treating this type of patient in clinical practice.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies II: Ultrasonography
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...