Related Experiment Video
Updated: Mar 26, 2026

Assessing Insulin Clearance in Mice via In Situ Liver Perfusion
Published on: December 13, 2024
Interstitial insulin kinetic parameters for a 2-compartment insulin model with saturable clearance
Christopher G Pretty1, Aaron Le Compte1, Sophie Penning2
1University of Canterbury, Centre for Bioengineering, Christchurch, New Zealand.
Abstract:
Glucose-insulin system models are commonly used for identifying insulin sensitivity. With physiological, 2-compartment insulin kinetics models, accurate kinetic parameter values are required for reliable estimates of insulin sensitivity. This study uses data from 6 published microdialysis studies to determine the most appropriate parameter values for the transcapillary diffusion rate (n(I)) and cellular insulin clearance rate (n(C)). The 6 studies (12 data sets) used microdialysis techniques to simultaneously obtain interstitial and plasma insulin concentrations. The reported plasma insulin concentrations were used as input and interstitial insulin concentrations were simulated with the interstitial insulin kinetics sub-model. These simulated results were then compared to the reported interstitial measurements and the most appropriate set of parameter values was determined across the 12 data sets by combining the results. Interstitial insulin kinetic parameters values n(I)=n(C)=0.0060 min⁻¹ were shown to be the most appropriate. These parameter values are associated with an effective, interstitial insulin half-life, t(½)=58 min, within the range of 25-130 min reported by others.
Related Concept Videos
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Two-Compartment Open Model: Extravascular Administration
The absorption exponent (ka) indicates the speed at which the drug...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...

